ASCENT Site: Yellowstone National Park
Instrument: Cooper Xact 625 Ambient Metals Monitor
Data Level: Level 2. Delivered, validated data in hourly resolution and standard atmospheric conditions.
Time Period: 2024-06-01 - 2024-06-30

ASCENT Data Policy
The ASCENT (Atmospheric Science and Chemistry mEasurement NeTwork) data are freely
 available to the public and the scientific community. Since these data are the product
 of extensive and continuous effort by the team to maintain ASCENT instrumentation and
 assure collection and processing of high quality data, we expect users of this data to
 ensure that the responsible ASCENT team members receive fair credit for their work, and
 are offered the opportunity to contribute to the data analysis and co-authored manuscripts,
 as appropriate. Note that co-authorship eligibility is not limited to writing sections of
 a paper but rather it encompasses the broader contribution to data collection and analysis.
 Early communication with ASCENT team members and individual site PIs (contact information
 available below) is expected to assure the quality and limitations of the data are accurately
 represented in the planned research.
When using these data in a publication or presentation, the National Science Foundation,
 Mid-scale Research Infrastructure (AGS 2131914), should be acknowledged. We suggest the following
 text be added to the acknowledgement section of publications:
 “The ASCENT data used in this work were supported by US NSF Mid-scale Research
 Infrastructure grant, AGS 2131914”.

Contacts
ASCENT PI: Nga Lee (Sally) Ng (ng@caltech.edu)
Site PI: Shane Murphey (shane.murphy@uwyo.edu)

Site Information
ASCENT Site Code: Yellowstone
ASCENT Site Number: 6
Coordinates: (-110.400996, 44.565217)
Elevation: 2442 (m above mean sea level)
Time Zone: America/Denver (UTC -7)

ASCENT Data Processing Version
0.1.19

Data Processing Details
Under typical operation, the measurements at timestamps of 00:00 do not include sampling from 00:00 to 00:30 due to internal instrument checks and calibrations.
 Different energy levels have been used. This change leads to higher MDL for several elements. For information, contact PI.

Xact Software Versions
Version, start date
1.2.2.109, 2024-05-31 16:00:00
1.2.2.109, 2024-06-01 16:00:00
1.2.2.109, 2024-06-10 16:00:00
1.2.2.109, 2024-06-11 16:00:00
1.2.2.109, 2024-06-12 16:00:00
1.2.2.109, 2024-06-13 16:00:00
1.2.2.109, 2024-06-14 16:00:00
1.2.2.109, 2024-06-15 16:00:00
1.2.2.109, 2024-06-16 16:00:00
1.2.2.109, 2024-06-17 16:00:00
1.2.2.109, 2024-06-18 16:00:00
1.2.2.109, 2024-06-19 16:00:00
1.2.2.109, 2024-06-20 16:00:00
1.2.2.109, 2024-06-21 16:00:00
1.2.2.109, 2024-06-22 16:00:00
1.2.2.109, 2024-06-23 16:00:00
1.2.2.109, 2024-06-24 16:00:00
1.2.2.109, 2024-06-25 16:00:00
1.2.2.109, 2024-06-26 16:00:00
1.2.2.109, 2024-06-27 16:00:00
1.2.2.109, 2024-06-28 16:00:00
1.2.2.109, 2024-06-29 16:00:00

Field Descriptions
site_number: ASCENT site number
site_code: ASCENT site code
sample_datetime_UTC: Datetime of sample start (UTC)
sample_type: 'sample'= an ambient sample, 'QC'= a quality control measurement
element: The measured element
concentration_ng_m3: Element concentration at ambient conditions (ng/m3)
uncertainty_ng_m3: Instrument concentration uncertainty calculated based on the most updated recommendation from manufacturer at ambient conditions (ng/m3)
sample_time_min: Instrument setting for sampling duration (min)
sample_analysis_id: An id that uniquely identifies this measurement in the respective table of the ASCENT database
site_record_id: An id that identifies this measurement in the respective table of the local site database
stp_factor: Multiplication conversion factor to standard temperature (0 degrees C) and pressure (101325 Pa)
concentration_stp_ng_m3: Element concentration at standard temperature and pressure (ng/m3)
uncertainty_stp_ng_m3: Instrumental concentration uncertainty calculated based on the most updated recommendation from manufacturer at standard temperature and pressure (ng/m3)
flag: Data quality flag(s) as defined by EBAS (ebas.nilu.no)
qc_outcome: An overall quality control outcome for this record (1-Good, 2-Not evaluated/Unknown, 3-Questionable, 4-Bad/Invalid, 9-Missing)
comment: Comments that provide more detail about any flags applied to the record
sample_time_est_min: Estimate of actual sampling time based on measured volume and flow rate (min)