experiment:
    id: '391'
    experiment_category:
        - 'Gas phase chemical reaction'
    experiment_date: '2014-01-02'
    temperature: '27'
    relative_humidity: '5'
    seeded_experiment: ''
    type_of_seed: ''
    seed_concentration_units: ''
    initial_seed_concentration_value: ''
    fuchs_adjusted_surface_area: ''
    reaction_type:
        - 'Photooxidation'
    oxidant_name: 'Hydroxyl radical'
    ro2_main_fate: 'HO2'
    ro2_lifetime_seconds: ''
    experiment_goals: "Low NO isoprene oxidation experiment to test the waters.\r\nInterested mainly in:\r\n-do instruments see the usual chemical compounds (ISOPOOH, IEPOX)\r\n-are instruments affected by ppm H2O2 levels\r\n-working out potential pitfalls in chamber method with this many instruments"
    experiment_summary: "Resolved initial issues with sampling lines and injection lines.\r\nInitial H2O2 addition may have been lower due to an eventually fixed issue with a lower injection line pressure. Isoprene injection proceeded as normally, but we started sampling before the prescribed 30 minutes of mixing for hydrocarbon (out of eagerness?). For future runs, it is probably advantageous to add hydrocarbon/standard first, then add H2O2. After approximately 30-45 minutes of sampling, instruments reported stable backgrounds so the full bank of UV lights were turned on. Based on initial reports, the chemistry proceeded as expected. Approximate calculation of RO2 reaction with NO vs. HO2 yielded  a 1:14 ratio in the initial (~10min) phase of the experiment, which is very good. Peak ISOPOOH was reached at ~1.5-2hrs into the experiment. Bag volume was checked at 23:17."
    additional_notes: "Instrument Status:\r\nTD LIF - up\r\nPTRMS - still down [waiting on a part]\r\nGTHOS - up\r\nLIF OHR - up, but OHR too high to measure. Was sampling for 1.5 h at the beginning. Will be down for tomorrow.\r\nCRM OHR - down [waiting on control board]\r\nNO CL - up\r\nGLY LIP - down [laser broken]\r\nFOR LIF - down \r\nI/A CIMS - up\r\nNCIMS - up\r\nRHTO3 - up\r\nGC FID - up\r\nAMS - up\r\nTQC1 - up\r\nTQC2 - up\r\nTOFCIMS - up\r\n\r\nBag Additions:\r\nIsoprene, ~50ppb (5uL ISOP, 98% purity)\r\nH2O2, ~2ppm (110 uL 50% H2O2)\r\n\r\nTimeline (UTC, hrs):\r\n16:48 - started H2O2 injection \r\n17:44 - stopped H2O2 injection \r\n18:02 - started ISOP injection \r\n18:06 - instruments started sampling from the bag\r\n18:12 - instruments were all confirmed to be sampling from the bag\r\n18:20 - stopped ISOP injection. All flows into bag stopped. \r\n18:57 - turned on all UV lights (config 1,2,3,4,5,6)\r\n18:58 - CIT-TQC2 estimated H2O2 ~1ppm\r\n18:58 - CIT-FID estimated isoprene ~45ppb\r\n23:14 - turned off all UV lights\r\n23:50 - all sampling ended. Added air into bag to dilute and flush."
    light_flux_characterization_id: '17'
    particle_loss_characterization_id: '13'
    vapor_loss_characterization_id: ''
    data_file_original_name: '20140102_expTimeline.csv'
    oxidant_concentration_units: 'molecules_per_cubic_centimeter'
    initial_oxidant_concentration_value: '1.5e6'
    reactants:
        -
            is_aerosol: ''
            pubchem_cid: '6557'
            reactant_name: 'ISOPRENE'
            not_in_pubchem: ''
            functional_group:
                - 'Alkene'
            concentration_units: 'parts_per_billion'
            functional_group_other: ''
            initial_concentration_value: '45'
        -
            is_aerosol: ''
            pubchem_cid: '784'
            reactant_name: 'hydrogen peroxide'
            not_in_pubchem: ''
            functional_group: []
            concentration_units: 'parts_per_million'
            functional_group_other: 'H2O2'
            initial_concentration_value: '2'
    skip_headers_timeline: '1'
    condensation_sink_rate_coefficient: ''
    is_draft: ''
    pressure: '750 Torr'
    doi: 'https://doi.org/10.5065/vfrr-y823'
    download_file_path: 'experiments/EXP_391.zip'
    experiment_link: 'https://icarus.ucdavis.edu/experiment/391'
    experiment_set_name: 'FIXCIT experiments'
    experiment_set_link: 'https://icarus.ucdavis.edu/experimentset/162'
    chamber_link: 'https://icarus.ucdavis.edu/chamber/545'
    chamber_name: 'Seinfeld chambers'
    experiment_name: '2014 FIXCIT Study_20140102_ISOPRENE/hydrogen peroxide_Hydroxyl radical_No Seed_Isoprene + OH, low NO, dry, no seeds'
    experiment_created_at: '2020-09-04 16:51:32'
    experiment_updated_at: '2021-10-07 00:56:33'
chamber:
    id: '545'
    name: 'Seinfeld chambers'
    chamber_flow_mode: 'Batch'
    chamber_shape: 'Rectangular Prism'
    chamber_volume_in_cubic_meters: '22'
    chamber_surface_area_in_square_meters: '48'
    flow_through_rate_in_liters_per_minute: ''
    chamber_body_material: 'Teflon'
    chamber_body_thickness_in_mils: '2'
    bag_replacement_date: ''
    bag_replacement_frequency: 'As needed'
    chamber_cleaning_method:
        - 'Flushing with air'
        - 'Flushing with air with UV lights on'
        - 'Oxidation'
    o3_background: '< 0.5 ppb'
    nox_background: '40 ppt'
    particle_background: '< 0.01 ug/m3'
    air_filtration_method: 'Custom filtration canisters to remove NOx, hydrocarbons, water, particles, ozone, SOx from pressurized ambient air.'
    mixing_fans: '1'
    mixing_fan_material: 'Pulsed air jets, manually actuated'
    temperature_control: '1'
    temperature_measurements_recorded: '1'
    temperature_range_min_degrees_celsius: '10'
    temperature_range_max_degrees_celsius: '45'
    humidity_control: '1'
    humidity_measurements_recorded: '1'
    relative_humidity_range_min_percent: '4'
    relative_humidity_range_max_percent: '90'
    particle_experiment_capability: '1'
    lights: '1'
    light_source_type: 'UV black lamps (350 nm centered)'
    link_to_supplemental_information: 'https://www.worldscientific.com/doi/abs/10.1142/9789813147355_0001'
    additional_notes: ''
    organization_id: '551'
    created_at: '2020-01-10T00:38:23.000000Z'
    updated_at: '2020-01-14T06:45:36.000000Z'
experimentSet:
    id: '162'
    name: 'FIXCIT experiments'
    experiment_set_description: 'The Focused Isoprene eXperiment at the California Institute of Technology (FIXCIT) was a collaborative study at the atmospheric chambers of Caltech during January 2014. FIXCIT is the laboratory component of SOAS, and is aimed toward (1) better understanding the chemical details behind ambient observations relevant to the southeastern United States, (2) advancing the knowledge of atmospheric oxidation mechanisms of important biogenic hydrocarbons, and (3) characterizing the behavior of field instrumentation using authentic standards. A series of chamber experiments was conducted to investigate the oxidation of isoprene, ?-pinene, methacrolein, pinonaldehyde, acylperoxy nitrates, isoprene hydroxy nitrates (ISOPN), isoprene hydroxy hydroperoxides (ISOPOOH), and isoprene epoxydiols (IEPOX). Pinonaldehyde and isomer-specific standards of ISOPN, ISOPOOH, and IEPOX were synthesized, enabling study of the oxidation mechanisms and instrument responses for these compounds.'
    chamber_id: '545'
    created_at: '2020-01-14T07:02:33.000000Z'
    updated_at: '2021-10-12T07:51:07.000000Z'
    time_units: 'Seconds past midnight'
    publications:
        44: 'https:/dx.doi.org/10.5194/acp-14-13531-2014'
    downloadFileSize: '52041362'
    download_file_path: 'experimentSets/EXPSET_162.zip'
    collaborators:
        -
            name_first: 'Allen'
            name_middle: 'H.'
            name_last: 'Goldstein'
            affiliation: 'UC Berkeley'
        -
            name_first: 'William'
            name_middle: 'H.'
            name_last: 'Brune'
            affiliation: 'Penn State University'
        -
            name_first: 'Ronald'
            name_middle: 'C.'
            name_last: 'Cohen'
            affiliation: 'UC Berkeley'
        -
            name_first: 'Delphine'
            name_middle: 'K.'
            name_last: 'Farmer'
            affiliation: 'Colorado State University'
        -
            name_first: 'Manjula'
            name_middle: 'R.'
            name_last: 'Canagaratna'
            affiliation: 'Aerodyne'
        -
            name_first: 'Douglas'
            name_middle: 'R.'
            name_last: 'Worsnop'
            affiliation: 'Aerodyne'
        -
            name_first: 'Jose'
            name_middle: 'L.'
            name_last: 'Jimenez'
            affiliation: 'University of Colorado Boulder'
        -
            name_first: 'Frank'
            name_middle: 'N.'
            name_last: 'Keutsch'
            affiliation: 'Harvard'
        -
            name_first: 'Saewung'
            name_middle: ''
            name_last: 'Kim'
            affiliation: 'UC Irvine'
        -
            name_first: 'Alex'
            name_middle: 'B.'
            name_last: 'Guenther'
            affiliation: 'UC Irvine'
        -
            name_first: 'John'
            name_middle: 'E.'
            name_last: 'Mak'
            affiliation: 'SUNY Stonybrook'
        -
            name_first: 'Geoffrey'
            name_middle: 'S.'
            name_last: 'Tyndall'
            affiliation: 'NCAR'
        -
            name_first: 'Denise'
            name_middle: 'D.'
            name_last: 'Montzka'
            affiliation: 'NCAR'
        -
            name_first: 'Andrew'
            name_middle: 'J.'
            name_last: 'Weinheimer'
            affiliation: 'NCAR'
        -
            name_first: 'Alam'
            name_middle: ''
            name_last: 'Hasson'
            affiliation: 'Fresno State'
organization:
    id: '551'
    lab_name: '2014 FIXCIT Study'
    lab_affiliation: 'California Institute of Technology'
    lab_currently_active: ''
    legal_constraints_statement: 'The Principal Investigator (PI) and institution retain any and all rights to the data that they generated. Use of ICARUS shared data in published materials or materials under review, including peer-reviewed publications or submissions, conference presentations, reports, and proposals, requires notification of the PI. For materials meant for dissemination that significantly depend on the data shared by specific PIs, the database user is required to offer the specific PI(s), and associated coworkers, co-authorship in said publications. When any of the ICARUS data are used in published materials, an acknowledgement statement should be included, recognizing the efforts of the ICARUS and NCAR DSET teams and support from the National Science Foundation.'
    access_constraints_statement: 'These data are openly accessible by all registered users. Accounts are available free of charge following the registration of user information with a valid email address.'
    additional_notes: ''
    created_at: '2020-01-10T00:15:51.000000Z'
    updated_at: '2020-01-11T04:55:16.000000Z'
    pi:
        -
            name_first: 'Paul'
            name_middle: 'O.'
            name_last: 'Wennberg'
            orcid: '0000-0002-6126-3854'
            phone: '626 395 2447'
            email: 'wennberg@caltech.edu'
        -
            name_first: 'John'
            name_middle: 'H.'
            name_last: 'Seinfeld'
            orcid: '0000-0003-1344-4068'
            phone: '626-395-4635'
            email: 'seinfeld@caltech.edu'
        -
            name_first: 'John'
            name_middle: 'D.'
            name_last: 'Crounse'
            orcid: '0000-0001-5443-729X'
            phone: '626-395-8655'
            email: 'crounjd@caltech.edu'
        -
            name_first: 'Tran'
            name_middle: 'B'
            name_last: 'Nguyen'
            orcid: '0000-0001-9206-4359'
            phone: '5307525987'
            email: 'tbn@ucdavis.edu'
    data_manager:
        -
            name_first: 'Tran'
            name_middle: 'B.'
            name_last: 'Nguyen'
            phone: '5307525987'
            email: 'tbn@ucdavis.edu'

---
UTC_hr,Action
16:48,started H2O2 injection 
17:44,stopped H2O2 injection 
18:02,started ISOP injection 
18:06,instruments started sampling from the bag
18:12,instruments were all confirmed to be sampling from the bag
18:20,stopped ISOP injection. All flows into bag stopped. 
18:57,turned on all UV lights (config 1;2;3;4;5;6)
18:58,CIT-TQC2 estimated H2O2 ~1ppm
18:58,CIT-FID estimated isoprene ~45ppb
23:14,turned off all UV lights
23:50,all sampling ended. Added air into bag to dilute and flush.