instrument_id: '417'
data_file_original_name: '201112_NB_GC.csv'
skip_headers: '1'
charts: ''
headers:
    - 'Scan_Number'
    - 'Time (America/Los_Angeles)'
    - 'Major peak (ppb)'
dataset_id: '3610'
experiment_link: 'https://icarus.ucdavis.edu/chambers/528/experiments/650'
experiment_set_link: 'https://icarus.ucdavis.edu/chambers/528/experimentSets/220'
chamber_link: 'https://icarus.ucdavis.edu/chambers/528'
dataset_created_at: '2021-09-25 15:49:25'
dataset_updated_at: '2021-09-25 15:49:25'
instrument_link: 'https://icarus.ucdavis.edu/chambers/528/instruments/417'
instrument:
    id: '417'
    short_name: 'GC - FID'
    full_name: 'Gas Chromatograph with Flame Ionization Detector'
    manufacturer: 'Hewlett Packard'
    model: '6890N'
    year: ''
    data_recording_software: 'HPCore Chemstation'
    data_analysis_software: ''
    raw_data_time_resolution: '14 min'
    analysis_data_averaging: ''
    detection_limit: '10 ppt'
    quantification_limit: ''
    sensitivity_to_temperature: ''
    sensitivity_to_relative_humidity: ''
    sampling_method: 'Direct Sampling'
    sample_preparation_method: ''
    sample_residence_time_in_seconds: ''
    length_of_tubing_in_cm: ''
    flow_rate: ''
    tubing_material: ''
    chemical_identification_method: ''
    data_analysis_method: 'Peak Area Integration'
    quantification_method: ''
    calibration_method: 'Calibration with a fourier transform infrared absorption spectrometer (FT-IR) and the absorption compounds of the chemical of interest from, e.g., PNNL, . Usually, this is performed by sampling from a pillow bag that is also used to sample for the FT-IR. . Also, serial dilutions'
    calibration_drift_estimate: 'Low (on the order of weeks)'
    calibration_schedule: 'As Needed'
    uncertainty_estimation_method: 'Depends on person integrating and each person should calculate this for themselves'
    known_interferences: ''
    link_to_supplemental_information: ''
    additional_notes: ''
    organization_id: '540'
    created_at: '2020-03-13T22:49:06.000000Z'
    updated_at: '2020-08-08T02:34:27.000000Z'
    column_descriptors: ''
    sampling_protocol: 'Online'
    skip_headers: '1'
    tubing_inner_diameter: ''
    what_is_measured: 'Gas-phase Compound Concentration'
    measurement_uncertainty: '10%'
    measurement_units: 'ppt'

---
Scan_Number,Time (America/Los_Angeles),Major peak (ppb)
7.000000,11/12/2020 18:00:20,611.868117
8.000000,11/12/2020 18:21:23,593.461228
9.000000,11/12/2020 18:42:21,616.478787
10.000000,11/12/2020 19:03:22,603.861605
11.000000,11/12/2020 19:24:19,599.391854
12.000000,11/12/2020 19:45:09,593.810391
13.000000,11/12/2020 20:06:05,608.672371
14.000000,11/12/2020 20:26:51,614.281037
15.000000,11/12/2020 20:47:51,593.189287
16.000000,11/12/2020 21:08:48,596.369343
17.000000,11/12/2020 21:29:40,604.373061
18.000000,11/12/2020 21:50:28,603.879303
19.000000,11/12/2020 22:11:19,457.924854
20.000000,11/12/2020 22:32:16,410.908448
21.000000,11/12/2020 22:53:09,416.809767
22.000000,11/12/2020 23:13:57,403.051420
23.000000,11/12/2020 23:34:47,392.494418
24.000000,11/12/2020 23:55:37,392.130666
25.000000,11/13/2020 00:16:24,399.592528
26.000000,11/13/2020 00:37:26,403.132904
27.000000,11/13/2020 00:58:13,392.029680
28.000000,11/13/2020 01:18:59,399.232503
29.000000,11/13/2020 01:39:50,395.073265
30.000000,11/13/2020 02:00:36,395.902063
31.000000,11/13/2020 02:21:29,380.374075
32.000000,11/13/2020 02:42:28,400.638305
33.000000,11/13/2020 03:03:15,385.378309
34.000000,11/13/2020 03:24:05,380.175194
35.000000,11/13/2020 03:44:49,382.167449
36.000000,11/13/2020 04:05:30,377.359184
37.000000,11/13/2020 04:26:24,381.904729
38.000000,11/13/2020 04:47:11,382.127495
39.000000,11/13/2020 05:08:02,379.028764
40.000000,11/13/2020 05:28:48,375.805269