instrument_id: '417'
data_file_original_name: '201016_NB_GC.csv'
skip_headers: '1'
charts: ''
headers:
    - 'Scan_Number'
    - 'Time (America/Los_Angeles)'
    - 'Major peak (ppb)'
dataset_id: '3575'
experiment_link: 'https://icarus.ucdavis.edu/chambers/528/experiments/643'
experiment_set_link: 'https://icarus.ucdavis.edu/chambers/528/experimentSets/220'
chamber_link: 'https://icarus.ucdavis.edu/chambers/528'
dataset_created_at: '2021-09-25 15:17:00'
dataset_updated_at: '2021-09-25 15:17:00'
instrument_link: 'https://icarus.ucdavis.edu/chambers/528/instruments/417'
instrument:
    id: '417'
    short_name: 'GC - FID'
    full_name: 'Gas Chromatograph with Flame Ionization Detector'
    manufacturer: 'Hewlett Packard'
    model: '6890N'
    year: ''
    data_recording_software: 'HPCore Chemstation'
    data_analysis_software: ''
    raw_data_time_resolution: '14 min'
    analysis_data_averaging: ''
    detection_limit: '10 ppt'
    quantification_limit: ''
    sensitivity_to_temperature: ''
    sensitivity_to_relative_humidity: ''
    sampling_method: 'Direct Sampling'
    sample_preparation_method: ''
    sample_residence_time_in_seconds: ''
    length_of_tubing_in_cm: ''
    flow_rate: ''
    tubing_material: ''
    chemical_identification_method: ''
    data_analysis_method: 'Peak Area Integration'
    quantification_method: ''
    calibration_method: 'Calibration with a fourier transform infrared absorption spectrometer (FT-IR) and the absorption compounds of the chemical of interest from, e.g., PNNL, . Usually, this is performed by sampling from a pillow bag that is also used to sample for the FT-IR. . Also, serial dilutions'
    calibration_drift_estimate: 'Low (on the order of weeks)'
    calibration_schedule: 'As Needed'
    uncertainty_estimation_method: 'Depends on person integrating and each person should calculate this for themselves'
    known_interferences: ''
    link_to_supplemental_information: ''
    additional_notes: ''
    organization_id: '540'
    created_at: '2020-03-13T22:49:06.000000Z'
    updated_at: '2020-08-08T02:34:27.000000Z'
    column_descriptors: ''
    sampling_protocol: 'Online'
    skip_headers: '1'
    tubing_inner_diameter: ''
    what_is_measured: 'Gas-phase Compound Concentration'
    measurement_uncertainty: '10%'
    measurement_units: 'ppt'

---
Scan_Number,Time (America/Los_Angeles),Major peak (ppb)
11.000000,10/16/2020 10:56:32,503.966329
12.000000,10/16/2020 11:17:14,500.174659
13.000000,10/16/2020 11:37:56,495.681609
14.000000,10/16/2020 11:58:30,507.000974
15.000000,10/16/2020 12:19:08,501.475877
16.000000,10/16/2020 12:39:51,488.636513
17.000000,10/16/2020 13:00:25,484.029650
18.000000,10/16/2020 13:21:08,491.069174
19.000000,10/16/2020 13:41:50,491.591610
20.000000,10/16/2020 14:02:28,498.026223
21.000000,10/16/2020 14:23:13,502.106517
22.000000,10/16/2020 14:43:53,505.699557
23.000000,10/16/2020 15:04:30,481.800151
24.000000,10/16/2020 15:25:14,476.962000
25.000000,10/16/2020 15:45:50,466.240095
26.000000,10/16/2020 16:06:27,470.517648
27.000000,10/16/2020 16:27:06,466.638683
28.000000,10/16/2020 16:47:48,453.994387
29.000000,10/16/2020 17:08:30,440.978832
30.000000,10/16/2020 17:29:04,454.625018
31.000000,10/16/2020 17:49:45,445.314036
32.000000,10/16/2020 18:10:26,442.767161
33.000000,10/16/2020 18:30:59,439.848816
34.000000,10/16/2020 18:51:38,434.920440
35.000000,10/16/2020 19:12:16,426.280927
36.000000,10/16/2020 19:32:55,425.134412
37.000000,10/16/2020 19:53:30,419.696230
38.000000,10/16/2020 20:14:07,420.994407
39.000000,10/16/2020 20:34:46,408.719588
40.000000,10/16/2020 20:55:24,409.609541