instrument_id: '378'
data_file_original_name: 'acetate3.csv'
skip_headers: '1'
charts: ''
headers:
    - 'Loss of Ethyl Acetate'
    - 'Acetic Acid'
    - 'Acetic Anhydride'
    - 'CH2O'
    - 'CO'
    - 'CO2'
dataset_id: '393'
experiment_link: 'https://icarus.ucdavis.edu/chambers/529/experiments/208'
experiment_set_link: 'https://icarus.ucdavis.edu/chambers/529/experimentSets/185'
chamber_link: 'https://icarus.ucdavis.edu/chambers/529'
dataset_created_at: '2020-05-21 08:57:25'
dataset_updated_at: '2020-12-11 21:35:04'
instrument_link: 'https://icarus.ucdavis.edu/chambers/529/instruments/378'
instrument:
    id: '378'
    short_name: 'FTIR'
    full_name: 'Bomem FTIR - First Floor Chamber'
    manufacturer: 'Bomem'
    model: 'DA3'
    year: '1986'
    data_recording_software: 'Bomem / Grams'
    data_analysis_software: 'Bomem / Grams'
    raw_data_time_resolution: '180 seconds'
    analysis_data_averaging: ''
    detection_limit: '10''s of ppb typical'
    quantification_limit: ''
    sensitivity_to_temperature: ''
    sensitivity_to_relative_humidity: ''
    sampling_method: ''
    sample_preparation_method: ''
    sample_residence_time_in_seconds: ''
    length_of_tubing_in_cm: ''
    flow_rate: ''
    tubing_material: ''
    chemical_identification_method: 'From standard infrared spectra, usually recorded in house.'
    data_analysis_method: 'Built-in spectral subtraction routines are used for quantification.'
    quantification_method: 'Beer''s Law absorption'
    calibration_method: ''
    calibration_drift_estimate: ''
    calibration_schedule: ''
    uncertainty_estimation_method: 'Derived from a combination of uncertainty in the absorption cross section (usually 3-5%), and the uncertainty in conducting the spectral subtraction.'
    known_interferences: ''
    link_to_supplemental_information: ''
    additional_notes: ''
    organization_id: '541'
    created_at: '2020-02-20T23:25:01.000000Z'
    updated_at: '2020-03-09T04:04:02.000000Z'
    column_descriptors: '[]'
    sampling_protocol: 'Online'
    skip_headers: '1'
    tubing_inner_diameter: ''
    what_is_measured: 'gas phase organics (including oxygenates, halogenated species and nitrates) and inorganics (e.g., CO, CO2, NO, NO2, HNO3, ...)'
    measurement_uncertainty: '+/- (5% + 2e12 molec cm-3) is typical'
    measurement_units: 'All measurements are molecule cm-3'

---
Loss of Ethyl Acetate,Acetic Acid,Acetic Anhydride,CH2O,CO,CO2
0,0,0,0,0,0
2.992E+13,1.69E+13,5.54688E+12,4.5E+12,5E+12,1.6E+13
5.049E+13,2.99E+13,1.24805E+13,7.5E+12,1.2E+13,3.4E+13
7.106E+13,3.9E+13,1.80274E+13,9E+12,2E+13,4.8E+13
9.163E+13,4.875E+13,2.35742E+13,6E+12,2.7E+13,5.6E+13