---
instrument_id: '417'
data_file_original_name: '170617.csv'
skip_headers: '1'
charts: ''
headers:
    - 'RH5%'
    - 'C12'
    - 'C13'
    - 'C14'
    - 'C14H28'
dataset_id: '799'
experiment_link: 'https://icarus.ucdavis.edu/chambers/548/experiments/313'
experiment_set_link: 'https://icarus.ucdavis.edu/chambers/548/experimentSets/203'
chamber_link: 'https://icarus.ucdavis.edu/chambers/548'
dataset_created_at: '2020-08-07 20:09:15'
dataset_updated_at: '2020-10-31 01:35:09'
instrument_link: 'https://icarus.ucdavis.edu/chambers/548/instruments/417'
instrument:
    id: '417'
    short_name: 'GC - FID'
    full_name: 'Gas Chromatograph with Flame Ionization Detector'
    manufacturer: 'Hewlett Packard'
    model: '6890N'
    year: ''
    data_recording_software: 'HPCore Chemstation'
    data_analysis_software: ''
    raw_data_time_resolution: '14 min'
    analysis_data_averaging: ''
    detection_limit: '10 ppt'
    quantification_limit: ''
    sensitivity_to_temperature: ''
    sensitivity_to_relative_humidity: ''
    sampling_method: 'Direct Sampling'
    sample_preparation_method: ''
    sample_residence_time_in_seconds: ''
    length_of_tubing_in_cm: ''
    flow_rate: ''
    tubing_material: ''
    chemical_identification_method: ''
    data_analysis_method: 'Peak Area Integration'
    quantification_method: ''
    calibration_method: 'Calibration with a fourier transform infrared absorption spectrometer (FT-IR) and the absorption compounds of the chemical of interest from, e.g., PNNL, . Usually, this is performed by sampling from a pillow bag that is also used to sample for the FT-IR. . Also, serial dilutions'
    calibration_drift_estimate: 'Low (on the order of weeks)'
    calibration_schedule: 'As Needed'
    uncertainty_estimation_method: 'Depends on person integrating and each person should calculate this for themselves'
    known_interferences: ''
    link_to_supplemental_information: ''
    additional_notes: ''
    organization_id: '540'
    created_at: '2020-03-13T22:49:06.000000Z'
    updated_at: '2020-08-08T02:34:27.000000Z'
    column_descriptors: ''
    sampling_protocol: 'Online'
    skip_headers: '1'
    tubing_inner_diameter: ''
    what_is_measured: 'Gas-phase Compound Concentration'
    measurement_uncertainty: '10%'
    measurement_units: 'ppt'

---
RH5%,C12,C13,C14,C14H28
09:27,3.971100,3.567500,3.177500,3.774300
10:11,4.036400,3.608900,3.136900,3.887500
10:56,3.915700,3.488000,3.019200,3.793400
11:40,3.879400,3.384900,3.063800,3.873300
12:24,3.870700,3.454300,2.937600,3.839400
13:08,3.898400,3.385500,3.001200,3.715400
13:52,3.832000,3.447500,2.938900,3.733000
14:36,3.797600,3.382000,2.969400,3.641300
15:21,3.838100,3.281400,2.975600,3.512400
16:05,3.857400,3.306600,2.857000,3.555500
16:49,3.748500,3.239000,2.834000,3.432500
17:33,3.746100,3.195500,2.777900,3.489500
18:17,3.688700,3.241400,2.825700,3.517600