instrument_id: '417'
data_file_original_name: '170620.csv'
skip_headers: '1'
charts: ''
headers:
    - 'RH88%'
    - 'C12'
    - 'C13'
    - 'C14'
    - 'C14H28'
dataset_id: '801'
experiment_link: 'https://icarus.ucdavis.edu/chambers/548/experiments/315'
experiment_set_link: 'https://icarus.ucdavis.edu/chambers/548/experimentSets/203'
chamber_link: 'https://icarus.ucdavis.edu/chambers/548'
dataset_created_at: '2020-08-07 20:11:40'
dataset_updated_at: '2020-10-25 16:52:29'
instrument_link: 'https://icarus.ucdavis.edu/chambers/548/instruments/417'
instrument:
    id: '417'
    short_name: 'GC - FID'
    full_name: 'Gas Chromatograph with Flame Ionization Detector'
    manufacturer: 'Hewlett Packard'
    model: '6890N'
    year: ''
    data_recording_software: 'HPCore Chemstation'
    data_analysis_software: ''
    raw_data_time_resolution: '14 min'
    analysis_data_averaging: ''
    detection_limit: '10 ppt'
    quantification_limit: ''
    sensitivity_to_temperature: ''
    sensitivity_to_relative_humidity: ''
    sampling_method: 'Direct Sampling'
    sample_preparation_method: ''
    sample_residence_time_in_seconds: ''
    length_of_tubing_in_cm: ''
    flow_rate: ''
    tubing_material: ''
    chemical_identification_method: ''
    data_analysis_method: 'Peak Area Integration'
    quantification_method: ''
    calibration_method: 'Calibration with a fourier transform infrared absorption spectrometer (FT-IR) and the absorption compounds of the chemical of interest from, e.g., PNNL, . Usually, this is performed by sampling from a pillow bag that is also used to sample for the FT-IR. . Also, serial dilutions'
    calibration_drift_estimate: 'Low (on the order of weeks)'
    calibration_schedule: 'As Needed'
    uncertainty_estimation_method: 'Depends on person integrating and each person should calculate this for themselves'
    known_interferences: ''
    link_to_supplemental_information: ''
    additional_notes: ''
    organization_id: '540'
    created_at: '2020-03-13T22:49:06.000000Z'
    updated_at: '2020-08-08T02:34:27.000000Z'
    column_descriptors: ''
    sampling_protocol: 'Online'
    skip_headers: '1'
    tubing_inner_diameter: ''
    what_is_measured: 'Gas-phase Compound Concentration'
    measurement_uncertainty: '10%'
    measurement_units: 'ppt'

---
RH88%,C12,C13,C14,C14H28
09:16,6.202900,5.435300,3.960100,5.116100
10:00,6.144000,5.581100,4.418400,5.396600
10:44,6.192700,5.685400,4.622800,5.536000
11:29,6.158800,5.752000,4.653400,5.618800
12:13,5.984100,5.835600,4.414100,5.469500
12:57,6.042400,5.538300,4.626700,5.623900
13:41,6.019300,5.526100,4.595400,5.565100
14:25,5.928900,5.509200,4.657700,5.635700
15:10,5.907200,5.580000,4.752100,5.801600
15:54,5.940900,5.540700,4.776200,5.861200
16:38,5.851100,5.449000,4.696800,5.709500
17:22,5.815800,5.404300,4.786400,5.786500
18:06,5.772600,5.255500,4.467100,5.513900
18:50,5.701400,5.387500,4.610100,5.443900
19:35,5.640900,5.176800,4.566800,5.454800
20:19,5.596500,5.114800,4.433700,5.423100
21:03,5.571400,5.072200,4.483400,5.511700
21:47,5.470000,4.955800,4.344300,5.427200
22:31,5.386900,5.044000,4.365000,5.407800
23:15,5.381800,4.921100,4.270400,5.250900
23:59,5.294200,4.836900,4.223800,5.234600
24:43,5.267300,4.884100,4.238600,5.152300
25:27,5.207500,4.823000,4.309300,5.227000
26:11,5.184100,4.720500,4.084600,5.041900
26:56,5.098300,4.677800,4.048900,5.084100
27:40,5.127300,4.646700,4.248900,5.186500
28:09,5.085300,4.484100,4.007500,4.928700