instrument_id: '417'
data_file_original_name: '170607.csv'
skip_headers: '1'
charts: ''
headers:
    - 'RH85%'
    - 'Isop'
    - 'MACR'
    - 'MVK'
dataset_id: '798'
experiment_link: 'https://icarus.ucdavis.edu/chambers/548/experiments/312'
experiment_set_link: 'https://icarus.ucdavis.edu/chambers/548/experimentSets/203'
chamber_link: 'https://icarus.ucdavis.edu/chambers/548'
dataset_created_at: '2020-08-07 20:06:59'
dataset_updated_at: '2020-11-17 22:43:45'
instrument_link: 'https://icarus.ucdavis.edu/chambers/548/instruments/417'
instrument:
    id: '417'
    short_name: 'GC - FID'
    full_name: 'Gas Chromatograph with Flame Ionization Detector'
    manufacturer: 'Hewlett Packard'
    model: '6890N'
    year: ''
    data_recording_software: 'HPCore Chemstation'
    data_analysis_software: ''
    raw_data_time_resolution: '14 min'
    analysis_data_averaging: ''
    detection_limit: '10 ppt'
    quantification_limit: ''
    sensitivity_to_temperature: ''
    sensitivity_to_relative_humidity: ''
    sampling_method: 'Direct Sampling'
    sample_preparation_method: ''
    sample_residence_time_in_seconds: ''
    length_of_tubing_in_cm: ''
    flow_rate: ''
    tubing_material: ''
    chemical_identification_method: ''
    data_analysis_method: 'Peak Area Integration'
    quantification_method: ''
    calibration_method: 'Calibration with a fourier transform infrared absorption spectrometer (FT-IR) and the absorption compounds of the chemical of interest from, e.g., PNNL, . Usually, this is performed by sampling from a pillow bag that is also used to sample for the FT-IR. . Also, serial dilutions'
    calibration_drift_estimate: 'Low (on the order of weeks)'
    calibration_schedule: 'As Needed'
    uncertainty_estimation_method: 'Depends on person integrating and each person should calculate this for themselves'
    known_interferences: ''
    link_to_supplemental_information: ''
    additional_notes: ''
    organization_id: '540'
    created_at: '2020-03-13T22:49:06.000000Z'
    updated_at: '2020-08-08T02:34:27.000000Z'
    column_descriptors: ''
    sampling_protocol: 'Online'
    skip_headers: '1'
    tubing_inner_diameter: ''
    what_is_measured: 'Gas-phase Compound Concentration'
    measurement_uncertainty: '10%'
    measurement_units: 'ppt'

---
RH85%,Isop,MACR,MVK
08:34,11.939700,8.339100,6.455000
08:50,11.870000,8.218700,6.382100
09:05,11.927900,8.312000,6.451200
09:21,11.899500,8.254700,6.400900
09:36,11.819900,8.222400,6.369300
09:52,11.884800,8.186300,6.375700
10:07,11.882700,8.224700,6.358200
10:23,11.855600,8.162300,6.321100
10:38,11.804500,8.228800,6.334900
10:54,11.738900,8.168000,6.339400
11:09,11.727600,8.202300,6.280400
11:25,11.714800,8.119700,6.246000
11:40,11.776600,8.184900,6.313500
11:56,11.682700,8.180400,6.307700
12:11,11.600800,8.094600,6.250600
12:27,11.610800,8.040900,6.227200
12:42,11.626100,8.075700,6.205800
12:57,11.522300,8.018000,6.177400
13:13,11.573800,7.988700,6.203800
13:28,11.508000,8.039600,6.119000
13:44,11.440800,7.901300,6.161500
13:59,11.493900,7.975900,6.152800
14:15,11.374800,7.908300,6.143500
14:30,11.388000,7.950100,6.104600
14:46,11.404300,7.908900,6.116000
15:01,11.330000,7.905600,6.106500
15:17,11.415800,7.901100,6.114600
15:32,11.281200,7.809000,6.026800
15:48,11.235000,7.890300,6.060900
16:03,11.093600,7.688900,5.904200
16:19,11.245800,7.750800,6.008300
16:34,11.082700,7.797800,6.050100
16:49,11.198700,7.755800,6.058200
17:05,11.081300,7.752100,5.958100
17:20,11.007300,7.714500,5.952700
17:36,11.054100,7.719600,5.942000
17:51,10.999300,7.680100,5.872000
18:07,10.956600,7.608500,5.915600
18:22,10.886700,7.671100,5.957200
18:38,10.886000,7.610100,5.869900
18:53,10.868700,7.591000,5.900900
19:09,10.889700,7.634200,5.829000
19:24,10.830100,7.491400,5.851400
19:40,10.658400,7.585800,5.822900
19:55,10.717600,7.529300,5.833400
20:10,10.783200,7.498300,5.779800