instrument_id: '378'
data_file_original_name: 'acetate26.csv'
skip_headers: '1'
charts: ''
headers:
    - 'Loss of Ethyl Acetate'
    - 'Acetic Acid'
    - 'Acetic Anhydride'
    - 'CH2O'
    - 'CO'
    - 'CO2'
    - 'Acetic Formic Anhydride'
dataset_id: '1550'
experiment_link: 'https://icarus.ucdavis.edu/chambers/529/experiments/468'
experiment_set_link: 'https://icarus.ucdavis.edu/chambers/529/experimentSets/185'
chamber_link: 'https://icarus.ucdavis.edu/chambers/529'
dataset_created_at: '2020-11-19 17:34:13'
dataset_updated_at: '2020-11-19 17:34:13'
instrument_link: 'https://icarus.ucdavis.edu/chambers/529/instruments/378'
instrument:
    id: '378'
    short_name: 'FTIR'
    full_name: 'Bomem FTIR - First Floor Chamber'
    manufacturer: 'Bomem'
    model: 'DA3'
    year: '1986'
    data_recording_software: 'Bomem / Grams'
    data_analysis_software: 'Bomem / Grams'
    raw_data_time_resolution: '180 seconds'
    analysis_data_averaging: ''
    detection_limit: '10''s of ppb typical'
    quantification_limit: ''
    sensitivity_to_temperature: ''
    sensitivity_to_relative_humidity: ''
    sampling_method: ''
    sample_preparation_method: ''
    sample_residence_time_in_seconds: ''
    length_of_tubing_in_cm: ''
    flow_rate: ''
    tubing_material: ''
    chemical_identification_method: 'From standard infrared spectra, usually recorded in house.'
    data_analysis_method: 'Built-in spectral subtraction routines are used for quantification.'
    quantification_method: 'Beer''s Law absorption'
    calibration_method: ''
    calibration_drift_estimate: ''
    calibration_schedule: ''
    uncertainty_estimation_method: 'Derived from a combination of uncertainty in the absorption cross section (usually 3-5%), and the uncertainty in conducting the spectral subtraction.'
    known_interferences: ''
    link_to_supplemental_information: ''
    additional_notes: ''
    organization_id: '541'
    created_at: '2020-02-20T23:25:01.000000Z'
    updated_at: '2020-03-09T04:04:02.000000Z'
    column_descriptors: '[]'
    sampling_protocol: 'Online'
    skip_headers: '1'
    tubing_inner_diameter: ''
    what_is_measured: 'gas phase organics (including oxygenates, halogenated species and nitrates) and inorganics (e.g., CO, CO2, NO, NO2, HNO3, ...)'
    measurement_uncertainty: '+/- (5% + 2e12 molec cm-3) is typical'
    measurement_units: 'All measurements are molecule cm-3'

---
Loss of Ethyl Acetate,Acetic Acid,Acetic Anhydride,CH2O,CO,CO2,Acetic Formic Anhydride
0,0,0,,0,0,0
2.60E+13,8.96E+12,1.45E+13,,,9.00E+12,7.02E+11
4.87E+13,1.53E+13,2.75E+13,,8.00E+12,1.70E+13,8.775E+11
7.03E+13,2.35E+13,3.81E+13,,9.00E+12,2.40E+13,1.872E+12
9.31E+13,2.86E+13,5.03E+13,,1.40E+13,3.10E+13,3.51E+12