date_of_characterization_experiment: '2008-03-01'
months_since_calibration: ''
measurement_technique: ''
j_no2_hz_at_max_lights: ''
j_h2o2_hz_at_max_lights: ''
j_o3_hz_at_max_lights: ''
total_number_of_lights: ''
light_percentage_on: '100'
light_source_type: ''
position_and_pattern_of_lights: 'Lights line two vertical sides of a cubic chamber'
data_collection_description: 'JNO2 value was calculated using measurements of NO and NO2 from a NOx Box and ozone from an O3 monitor.'
data_analysis_description: 'JNO2 values were calculated using the equation JNO2 = k(O3+NO)*[O3]*[NO]/[NO2], with k(O3+NO) = 1.9e-14 cm3molec-1s-1.'
link_to_supplemental_information: ''
additional_notes: ''
data_file_original_name: 'JNO2_MouseHouse_March2008.csv'
instrument_id: '431'
light_intensity: ''
chamber_id: '557'
name: 'JNO2_MouseHouse'
characterization_link: 'https://icarus.ucdavis.edu/lightFluxCharacterizations/44'
characterization_created_at: '2022-01-11 11:41:18'
characterization_updated_at: '2022-01-11 11:41:18'

---
?Lights_%,JNO2
10,0.071
20,0.1405
30,0.211
50,0.3195
70,0.3975
100,0.5725