instrument_id: '501'
data_file_original_name: 'Figure_S1.csv'
skip_headers: '1'
charts: ''
headers:
    - 'Exp Condition'
    - 'QSA'
    - 'tCI'
    - '[BASE]'
    - 'A1 (MTE Corrected)'
    - 'A2 (MTE Corrected)'
    - 'MSA1 (MTE Corrected)'
    - 'Particle Concentration'
    - 'Particle counts std.'
    - '[SAi]'
    - "[MSAi]\rTMA&MSA (1nm cutpoint)"
    - '200'
    - '0.019242611'
    - '7'
    - '2.07E+08'
    - '2.25E+06'
    - '2.56E+09'
    - '1576'
    - '290'
    - '6.36E+07'
    - "2020072939\rTMA&MSA (2nm cutpoint)"
    - '200'
    - '0.019242611'
    - '7'
    - '2.20E+08'
    - '2.27E+06'
    - '2.63E+09'
    - '37'
    - '12'
    - '6.36E+07'
    - '2020072939'
dataset_id: '4263'
experiment_link: 'https://icarus.ucdavis.edu/chambers/562/experiments/869'
experiment_set_link: 'https://icarus.ucdavis.edu/chambers/562/experimentSets/258'
chamber_link: 'https://icarus.ucdavis.edu/chambers/562'
dataset_created_at: '2023-03-03 10:23:35'
dataset_updated_at: '2023-03-03 10:23:35'
instrument_link: 'https://icarus.ucdavis.edu/chambers/562/instruments/501'
instrument:
    id: '501'
    short_name: 'vwCPC'
    full_name: 'versatile water-based condensation particle counter'
    manufacturer: 'TSI'
    model: 'vwCPC 3789'
    year: 'n/a'
    data_recording_software: 'AIM'
    data_analysis_software: 'n/a'
    raw_data_time_resolution: '1 Hz'
    analysis_data_averaging: 'n/a'
    detection_limit: '1 nanometer cut-point'
    quantification_limit: ''
    sensitivity_to_temperature: ''
    sensitivity_to_relative_humidity: ''
    sampling_method: ''
    sample_preparation_method: ''
    sample_residence_time_in_seconds: ''
    length_of_tubing_in_cm: '5'
    flow_rate: '1.5 lpm'
    tubing_material: 'Stainless Steel'
    chemical_identification_method: ''
    data_analysis_method: ''
    quantification_method: ''
    calibration_method: ''
    calibration_drift_estimate: 'No estimate'
    calibration_schedule: ''
    uncertainty_estimation_method: "Particle uncertainty could be estimated with the use of an SMPS and electrometer sampling in-tandem with the vwCPC. This has been done previously to show the size cut-off for the CPC.\r\nAdditionally, the manual states that particle concentrations are +/- 5% when total concentrations are over 200,000. This could be considered the maximum error."
    known_interferences: ''
    link_to_supplemental_information: ''
    additional_notes: ''
    organization_id: '557'
    created_at: '2022-01-14T13:13:15.000000Z'
    updated_at: '2022-01-14T13:13:15.000000Z'
    column_descriptors: ''
    sampling_protocol: 'Online'
    skip_headers: '1'
    tubing_inner_diameter: '1/8 inch'
    what_is_measured: 'Aerosol particles down to 1-nm in size'
    measurement_uncertainty: 'particle concentrations over 200,00 have an uncertainty of +/- 5%'
    measurement_units: '(#/cm^3)'

---
Exp Condition,QSA,tCI,[BASE],A1 (MTE Corrected),A2 (MTE Corrected),MSA1 (MTE Corrected),Particle Concentration,Particle counts std.,[SAi],[MSAi]
TMA&MSA (1nm cutpoint),200,0.019242611,7,2.07E+08,2.25E+06,2.56E+09,1576,290,6.36E+07,2020072939
TMA&MSA (2nm cutpoint),200,0.019242611,7,2.20E+08,2.27E+06,2.63E+09,37,12,6.36E+07,2020072939