instrument_id: '417'
data_file_original_name: '130414_GCFID.csv'
skip_headers: '1'
charts: ''
headers:
    - 'Exp_time(min)'
    - 'Isoprene(ppb)'
    - 'Methacrolein (ppb)'
    - 'Methylvinylketone (ppb)'
    - 'Cyclohexane (ppb)'
dataset_id: '3523'
experiment_link: 'https://icarus.ucdavis.edu/chambers/553/experiments/627'
experiment_set_link: 'https://icarus.ucdavis.edu/chambers/553/experimentSets/217'
chamber_link: 'https://icarus.ucdavis.edu/chambers/553'
dataset_created_at: '2021-09-01 21:48:24'
dataset_updated_at: '2021-09-01 21:48:24'
instrument_link: 'https://icarus.ucdavis.edu/chambers/553/instruments/417'
instrument:
    id: '417'
    short_name: 'GC - FID'
    full_name: 'Gas Chromatograph with Flame Ionization Detector'
    manufacturer: 'Hewlett Packard'
    model: '6890N'
    year: ''
    data_recording_software: 'HPCore Chemstation'
    data_analysis_software: ''
    raw_data_time_resolution: '14 min'
    analysis_data_averaging: ''
    detection_limit: '10 ppt'
    quantification_limit: ''
    sensitivity_to_temperature: ''
    sensitivity_to_relative_humidity: ''
    sampling_method: 'Direct Sampling'
    sample_preparation_method: ''
    sample_residence_time_in_seconds: ''
    length_of_tubing_in_cm: ''
    flow_rate: ''
    tubing_material: ''
    chemical_identification_method: ''
    data_analysis_method: 'Peak Area Integration'
    quantification_method: ''
    calibration_method: 'Calibration with a fourier transform infrared absorption spectrometer (FT-IR) and the absorption compounds of the chemical of interest from, e.g., PNNL, . Usually, this is performed by sampling from a pillow bag that is also used to sample for the FT-IR. . Also, serial dilutions'
    calibration_drift_estimate: 'Low (on the order of weeks)'
    calibration_schedule: 'As Needed'
    uncertainty_estimation_method: 'Depends on person integrating and each person should calculate this for themselves'
    known_interferences: ''
    link_to_supplemental_information: ''
    additional_notes: ''
    organization_id: '540'
    created_at: '2020-03-13T22:49:06.000000Z'
    updated_at: '2020-08-08T02:34:27.000000Z'
    column_descriptors: ''
    sampling_protocol: 'Online'
    skip_headers: '1'
    tubing_inner_diameter: ''
    what_is_measured: 'Gas-phase Compound Concentration'
    measurement_uncertainty: '10%'
    measurement_units: 'ppt'

---
Exp_time(min),Isoprene(ppb),Methacrolein (ppb),Methylvinylketone (ppb),Cyclohexane (ppb)
0,49.405,0,0,11597.04
16,30.955,4.577708,5.4313,11597.04
32,22.14,6.984951,6.478765,11351.6
48,16.0925,10.063065,6.67274,NaN
64,11.7875,10.26038,5.81925,11198.2
80,8.9995,11.128566,6.36238,11428.3
96,6.191,11.010177,5.66407,NaN
112,5.3095,11.246955,6.090815,11474.32
128,4.0795,11.957289,4.771785,NaN
144,3.116,12.272993,4.383835,11428.3
160,1.845,11.957289,3.72432,NaN
176,1.025,12.115141,2.909625,11458.98
192,0.4715,11.720511,2.63806,NaN
208,0,11.799437,3.530345,11366.94