instrument_id: '417'
data_file_original_name: '131111_GCFID.csv'
skip_headers: '1'
charts: ''
headers:
    - 'Exp_time(min)'
    - 'Butadiene(ppb)'
    - 'Acrolein(ppb)'
dataset_id: '3571'
experiment_link: 'https://icarus.ucdavis.edu/chambers/553/experiments/642'
experiment_set_link: 'https://icarus.ucdavis.edu/chambers/553/experimentSets/218'
chamber_link: 'https://icarus.ucdavis.edu/chambers/553'
dataset_created_at: '2021-09-01 22:42:03'
dataset_updated_at: '2021-09-01 22:42:03'
instrument_link: 'https://icarus.ucdavis.edu/chambers/553/instruments/417'
instrument:
    id: '417'
    short_name: 'GC - FID'
    full_name: 'Gas Chromatograph with Flame Ionization Detector'
    manufacturer: 'Hewlett Packard'
    model: '6890N'
    year: ''
    data_recording_software: 'HPCore Chemstation'
    data_analysis_software: ''
    raw_data_time_resolution: '14 min'
    analysis_data_averaging: ''
    detection_limit: '10 ppt'
    quantification_limit: ''
    sensitivity_to_temperature: ''
    sensitivity_to_relative_humidity: ''
    sampling_method: 'Direct Sampling'
    sample_preparation_method: ''
    sample_residence_time_in_seconds: ''
    length_of_tubing_in_cm: ''
    flow_rate: ''
    tubing_material: ''
    chemical_identification_method: ''
    data_analysis_method: 'Peak Area Integration'
    quantification_method: ''
    calibration_method: 'Calibration with a fourier transform infrared absorption spectrometer (FT-IR) and the absorption compounds of the chemical of interest from, e.g., PNNL, . Usually, this is performed by sampling from a pillow bag that is also used to sample for the FT-IR. . Also, serial dilutions'
    calibration_drift_estimate: 'Low (on the order of weeks)'
    calibration_schedule: 'As Needed'
    uncertainty_estimation_method: 'Depends on person integrating and each person should calculate this for themselves'
    known_interferences: ''
    link_to_supplemental_information: ''
    additional_notes: ''
    organization_id: '540'
    created_at: '2020-03-13T22:49:06.000000Z'
    updated_at: '2020-08-08T02:34:27.000000Z'
    column_descriptors: ''
    sampling_protocol: 'Online'
    skip_headers: '1'
    tubing_inner_diameter: ''
    what_is_measured: 'Gas-phase Compound Concentration'
    measurement_uncertainty: '10%'
    measurement_units: 'ppt'

---
Exp_time(min),Butadiene(ppb),Acrolein(ppb)
0,127.4595,0
15,108.3555,4.41
30,97.6095,7.448
45,88.953,11.123
60,80.8935,13.426
75,74.625,17.444
90,68.655,19.306
105,65.073,21.315
120,57.0135,23.275
135,52.2375,25.578
150,48.0585,26.46
165,43.8795,28.175
180,40.2975,29.596
195,37.611,31.164
210,34.626,31.997
225,30.447,33.075
240,29.22315,34.153
255,25.58145,34.839
270,24.32775,35.819
285,22.23825,36.309
300,20.8353,37.142
315,19.67115,37.289
330,17.9697,37.975
345,15.96975,38.22
360,14.5668,38.171
375,13.6116,38.367
390,12.92505,38.514